Zhejiang Orient Gene Biotech Co.,Ltd

Zhejiang Orient Gene Biotech Co.,Ltd

Zhejiang,China

Zhejiang Orient Gene Biotech Co.,Ltd

Zhejiang,China

favorite supplier

verified Copper Member
Zhejiang Orient Gene Biotech Co.,Ltd
favorite supplier

Zhejiang Orient Gene Biotech Co.,Ltd

Zhejiang,China

Scan QR code

Access to mobile station

Clear All
Alternate Text

Urinalysis Strip & Analyzer

FOB Price : Get a Price/Quote

Min.Order : 500 Box(es)

Certification : CFDA,GMP,ISO13485,CE,FDA

Brand Name : Healgen / Orient Gene

Payment Terms : L/C,T/T,D/P

share :

product information

  • brand name : Healgen / Orient Gene

  • certification : CFDA,GMP,ISO13485,CE,FDA

  • min.order : 500 Box(es)

  • warranty :

  • payment terms : L/C,T/T,D/P

  • Packaging :

  • Specification :

  • place of origin : Zhejiang

product description

Model: Strip                                                                             Certification: £  ISO 9001  ¢ ISO13485  ¢  CE  ¢  FDA

Dimension: /                                                                             Packaging Details: 100 strips/box

Brand Name: Healgen, Orient Gene                                         Place of Origin: China

Warranty: 24 months                                                               Color: /

Size: /                                                                                       Finish: /

Customer's Logo: /                                                                  MOQ: 500 boxes

Processing Time: /                                                                   Usage: In vitro diagnosis

Quality: /                                                                                  Packaging: 100 strips/box

The Urine Reagent Strips (URS) for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, Urine Reagent Strips provide tests in urine for up to 14 different items.


Ordering Information
Product Description Specimen Format Cut-off Value Kit Size
Ascorbateà Urine Strip 0.5-0.6 mmol/L 100 Tests/Canister
Bilirubin√† Urine Strip 8.6-17 μmol/L 100 Tests/Canister
Blood√† Urine Strip 5-15 Ery/μL 100 Tests/Canister
Ca√ Urine Strip 2.5 mmol/L 100 Tests/Canister
Creatinine√ Urine Strip 50 mg/dL 100 Tests/Canister
Gluoseà Urine Strip 2.8~5.5 mmol/L 100 Tests/Canister
Ketoneà Urine Strip 0.5~1.0 mmol/L 100 Tests/Canister
Leukocytes√† Urine Strip 5-15 Leuko/μL 100 Tests/Canister
Micro Albumin√ Urine Strip 0.08~0.15 mg/dL 100 Tests/Canister
Nitrite√† Urine Strip 13~22 μmol/L 100 Tests/Canister
pHà Urine Strip 0.5 100 Tests/Canister
Proteinà Urine Strip 0.15~0.3 g/L 100 Tests/Canister
Specific Gravityà Urine Strip 0.005 100 Tests/Canister
Urobilinogen√† Urine Strip 3.3-16 μmol/L 100 Tests/Canister
√ CE Marked       † Cleared for US 510(k)

The Urine Analyzer is intended to be used with the urinalysis strips for clinical urine testing. The urinalysis strip could detect Urobilinogen, Bilirubin, Ketone (acetoacetic acid), Occult blood, Protein, Nitrite, Leukocytes, Glucose, Specific Gravity, pH, Vitamin C, Microalbumin or Creatinine in human urine.

Technical Specification
Model Healgen 500
Test mode One step (60 pieces/hour), Slow (60 pieces/hour), Fast (120 pieces/hour)
Display LCD, resolution: 320*240
Principle RGB tricolor test theory
Communication interface Standard RS232 interface, USB interface
Repeatability CV≤1%
Stability CV≤1%
Record mode Micro-thermal printer, LCD, Flash ROM data storage.
Printer Built-in micro-thermal printer, row width for the paper: 57mm
Operation temperature 10℃~30℃
Relative humidity ≤80%
Power supply 100-240VAC  50/60Hz
Fuse T1.6AL250V
Dimension 240mm(L)*220mm(W)*130mm(H)
 
Model Healgen 501
Test mode Single-step test
Display LCD, resolution: 320*240
Principle RGB tricolor test theory
Communication interface Micro USB interface, Bluetooth wireless communication (optional Bluetooth)
Repeatability CV≤1%
Stability CV≤1%
Record mode LCD display, Flash ROM data storage
Relative humidity ≤80%
Power supply Built-in rechargeable lithium battery 3.7V, 1900mAh
Host computer: DC 5V, 1A
Adapter: AC 100V~240V, 50/60Hz
Operating environment Temperature: 10℃~30℃
Relative humidity: ≤80%
Atmospheric pressure: 76kPa~106kPa
Away from the strong electric field (magnetic field), avoid direct sunlight
Dimension 126mm(L)*73.5mm(W)*30mm(H)


 

People who viewed this also viewed

  • HCV Rapid Test Cassette

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Strep A Rapid Test

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Colloidal Gold Test Reader

    FOB Price :

    Min.Order : 10 Set(s)

  • LH One Step Ovulation Test

    FOB Price :

    Min.Order : 2000 Piece(s)

  • hCG One Step Pregnancy Test

    FOB Price :

    Min.Order : 2000 Piece(s)

Urinalysis Strip & Analyzer
share :

product information

product description

Model: Strip                                                                             Certification: £  ISO 9001  ¢ ISO13485  ¢  CE  ¢  FDA

Dimension: /                                                                             Packaging Details: 100 strips/box

Brand Name: Healgen, Orient Gene                                         Place of Origin: China

Warranty: 24 months                                                               Color: /

Size: /                                                                                       Finish: /

Customer's Logo: /                                                                  MOQ: 500 boxes

Processing Time: /                                                                   Usage: In vitro diagnosis

Quality: /                                                                                  Packaging: 100 strips/box

The Urine Reagent Strips (URS) for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, Urine Reagent Strips provide tests in urine for up to 14 different items.


Ordering Information
Product Description Specimen Format Cut-off Value Kit Size
Ascorbateà Urine Strip 0.5-0.6 mmol/L 100 Tests/Canister
Bilirubin√† Urine Strip 8.6-17 μmol/L 100 Tests/Canister
Blood√† Urine Strip 5-15 Ery/μL 100 Tests/Canister
Ca√ Urine Strip 2.5 mmol/L 100 Tests/Canister
Creatinine√ Urine Strip 50 mg/dL 100 Tests/Canister
Gluoseà Urine Strip 2.8~5.5 mmol/L 100 Tests/Canister
Ketoneà Urine Strip 0.5~1.0 mmol/L 100 Tests/Canister
Leukocytes√† Urine Strip 5-15 Leuko/μL 100 Tests/Canister
Micro Albumin√ Urine Strip 0.08~0.15 mg/dL 100 Tests/Canister
Nitrite√† Urine Strip 13~22 μmol/L 100 Tests/Canister
pHà Urine Strip 0.5 100 Tests/Canister
Proteinà Urine Strip 0.15~0.3 g/L 100 Tests/Canister
Specific Gravityà Urine Strip 0.005 100 Tests/Canister
Urobilinogen√† Urine Strip 3.3-16 μmol/L 100 Tests/Canister
√ CE Marked       † Cleared for US 510(k)

The Urine Analyzer is intended to be used with the urinalysis strips for clinical urine testing. The urinalysis strip could detect Urobilinogen, Bilirubin, Ketone (acetoacetic acid), Occult blood, Protein, Nitrite, Leukocytes, Glucose, Specific Gravity, pH, Vitamin C, Microalbumin or Creatinine in human urine.

Technical Specification
Model Healgen 500
Test mode One step (60 pieces/hour), Slow (60 pieces/hour), Fast (120 pieces/hour)
Display LCD, resolution: 320*240
Principle RGB tricolor test theory
Communication interface Standard RS232 interface, USB interface
Repeatability CV≤1%
Stability CV≤1%
Record mode Micro-thermal printer, LCD, Flash ROM data storage.
Printer Built-in micro-thermal printer, row width for the paper: 57mm
Operation temperature 10℃~30℃
Relative humidity ≤80%
Power supply 100-240VAC  50/60Hz
Fuse T1.6AL250V
Dimension 240mm(L)*220mm(W)*130mm(H)
 
Model Healgen 501
Test mode Single-step test
Display LCD, resolution: 320*240
Principle RGB tricolor test theory
Communication interface Micro USB interface, Bluetooth wireless communication (optional Bluetooth)
Repeatability CV≤1%
Stability CV≤1%
Record mode LCD display, Flash ROM data storage
Relative humidity ≤80%
Power supply Built-in rechargeable lithium battery 3.7V, 1900mAh
Host computer: DC 5V, 1A
Adapter: AC 100V~240V, 50/60Hz
Operating environment Temperature: 10℃~30℃
Relative humidity: ≤80%
Atmospheric pressure: 76kPa~106kPa
Away from the strong electric field (magnetic field), avoid direct sunlight
Dimension 126mm(L)*73.5mm(W)*30mm(H)


 

Recommend

Join Free

Create New Account

Leave your contact information for the suppliers. If you're our member, Please Sign In to use your account information.

Sign in