ARTERIOSCLEROSIS INDEX MEASURING INSTRUMENT

FOB Price : Get a Price/Quote

Min.Order : 1 Piece(s)

Certification : CFDA

Brand Name : Osachi(LangFang)Medical Technology Co., Ltd

Payment Terms : L/C,T/T,D/P,WesternUnion

share :

product information

  • brand name : Osachi(LangFang)Medical Technology Co., Ltd

  • certification : CFDA

  • min.order : 1 Piece(s)

  • warranty : 5 years

  • payment terms : L/C,T/T,D/P,WesternUnion

  • Packaging : Single pack, 1 piece/pack.

  • Specification : Approximately Wideth 110mm*Breath110mm*Height 140mm

  • place of origin : Shaanxi

product description

[Product description] 
               1.Constitute of Product
               The product is composed of main case and cuff.
               2.Structure of Product
[Product performance] 1.blood pressure measurement range:0~280mmHg(0~37.3kpa).
                                        2.pulse measurement range:40~180times/min;pulse error:±5%
                                        3.arterial stiffness index(ASI):
                                                       normal(ideal):≤70       
                                                       normal(High Value):71~80     
                                                       normal to medium:81~160
                                                       medium to heavy:>160
                                       4.resolution:display resotion is 1mmHg(0.133kpa)
                                       5.pressure sensor accuracy:Maxium error of pressure measurement in the cuff
shall be ±0.4kpa(±3mmHg)at any mesuring point  in the range.
[Intended use] Use to measure the systolic,diastolic,pulse,and measure the pulse waveform of the artery when the press changes,and analyze the elasticity of the artery and the degree of atherosclerosis.The values are for clinical reference only.
[Instructions for use] 
1.Battery Installation..
2. Power adapter connection.
3.Cuff  Installation.
4.Definition of opertion modes.
5.Setting mode:setting of user,date,time,unite,etc.
6.Measure mode:process of measuring blood pressure,pulse,ASI and  presume vascular age.

People who viewed this also viewed

  • Knee fixator

    FOB Price :

    Min.Order : 1 Piece(s)

  • Lumbar fixator

    FOB Price :

    Min.Order : 1 Piece(s)

  • ARTERIOSCLEROSIS INDEX MEASURING INSTRUMENT

    FOB Price :

    Min.Order : 1 Piece(s)

  • Hip fixator

    FOB Price :

    Min.Order : 1 Piece(s)

  • Medical Molecular Sieve Oxygen System

    FOB Price :

    Min.Order : 1 Piece(s)

Shaanxi Orthopaedic Medical Co.,Ltd

Ordinary verified

Business Type Manufacturer

Country / Region Shaanxi,China

Main Products Others, Orthopedics & Immobilization, Implants & Prosthetics, Contract Manufacturing, Quality Management

Main Markets

ARTERIOSCLEROSIS INDEX MEASURING INSTRUMENT
share :

product information

product description

[Product description] 
               1.Constitute of Product
               The product is composed of main case and cuff.
               2.Structure of Product
[Product performance] 1.blood pressure measurement range:0~280mmHg(0~37.3kpa).
                                        2.pulse measurement range:40~180times/min;pulse error:±5%
                                        3.arterial stiffness index(ASI):
                                                       normal(ideal):≤70       
                                                       normal(High Value):71~80     
                                                       normal to medium:81~160
                                                       medium to heavy:>160
                                       4.resolution:display resotion is 1mmHg(0.133kpa)
                                       5.pressure sensor accuracy:Maxium error of pressure measurement in the cuff
shall be ±0.4kpa(±3mmHg)at any mesuring point  in the range.
[Intended use] Use to measure the systolic,diastolic,pulse,and measure the pulse waveform of the artery when the press changes,and analyze the elasticity of the artery and the degree of atherosclerosis.The values are for clinical reference only.
[Instructions for use] 
1.Battery Installation..
2. Power adapter connection.
3.Cuff  Installation.
4.Definition of opertion modes.
5.Setting mode:setting of user,date,time,unite,etc.
6.Measure mode:process of measuring blood pressure,pulse,ASI and  presume vascular age.