Plasma sterilizer. PS-120 chamber size: 120 liters | ||
No | Content | Parameter |
1 | Application range | The product is used for rapid sterilization of surgical instruments, fear of heat, fear of moisture, orthopedic drills, electric knives, high-tech materials, vinyl materials, and rigid endoscopes Sterilization of anesthesia and respiratory equipment circuits, Sterilization of plastic and rubber products, Sterilization of other thermolabile instruments and expensive equipment: |
2 | Sterilization system | Low temperature plasma sterilization system |
3 | Chamber volume | Effective volume≥60L |
4 | Sterilization temperature | 50℃~60℃ |
5 | Chamber shape | Rectangular shape |
6 | Door | Single manual door |
7 | Door heating | Power 900W, preheating time ≤30min, heating film number ≥2, door panel temperature maintained within 55℃ to prevent condensation of hydrogen peroxide gas |
8 | Sterilization agent | Hydrogen peroxide with a concentration of ≥60%, sealed installation, with automatic identification system |
9 | Injection type | Cartridge injection: plastic package. Cartridges validity: 18months. Built-in intelligent chip will reminder system alarm when the cartridges are not valid any more. Automatic disposal of used containers in the disposal compartment: The product injection method has independent intellectual property rights, which can avoid disputes caused by property rights during the use process. |
10 | Sterilizer dosage | ≤2mL, dosage error <1%, PH<2.6, content drop rate <3.04% after being placed at 54℃ for 14 days, and provide a test report above the provincial level. |
11 | Plasma power | Power ≤500W, strong resolution ability, 0.01mg/cm2 residue in stainless steel after sterilization |
12 | Sterilization program | Three programs: standard, accelerated, extended: |
13 | Sterilization time | ≤60min |
14 | LCD display | ≥The 7-inch ultra-clear LCD screen makes the operation and viewing more clear and direct. Lively display. |
15 | Main body insulation | Two or more thermal insulation materials keep the cavity insulate, the thickness is ≥20mm, and the thermal insulation materials are required to have the characteristics of low thermal conductivity, good fire resistance, anti-aging, environmental protection and non-toxicity.。 |
16 | *Vacuum pump | Germany LEYBOLD |
17 | Vacuum pump protection device | Equipped with a vacuum pump protector, which can prevent the occurrence of oil reversal of the vacuum pump to the sterilization chamber due to the change of the power supply phase sequence |
18 | Oil mist filter | The product has an exhaust oil mist filter system, which can recover oil mist, prevent oil mist from entering the air, and through the pump suction, return the pump oil to the pump for repeated use to reduce fuel consumption. |
19 | Pressure sensing device | The product is equipped with a pressure sensing device that can sense the outdoor pressure, the pressure of the purification device and the sterilization chamber, and the measurement range is 0~101KPa |
20 | Vacuum control valve | Using high vacuum baffle solenoid valve to control the vacuum pipeline, the leakage rate <1.3*10-7Pa*L*S-1 |
21 | Pipe material | Use 304 stainless steel sanitary pipe and stainless steel sanitary clamp connection |
22 | Precision intake filter system | Filter level≤0.2um |
23 | *Plasma discharge monitoring device | Monitor the generation of plasma in the plasma sterilizer, and monitor the sterilization effect of the sterilizer by monitoring the plasma |
24 | *Number of RF sources | Double sets of radio frequency sources, increase the average density of plasma, enhance the penetration ability of plasma, and improve the sterilization ability |
25 | *AC and DC hybrid ignition device with self-check function | First use direct current to conduct the sterilization chamber, and then use alternating current to continuously generate plasma, making the generation of plasma easier and more stable |
26 | Printing system | Built-in thermographic printer: Various parameters such as sterilization time, inner tank temperature, liquid injection volume, vacuum pressure, and operators can be automatically printed out during the sterilization process. And can keep the printed records for more than five years for a long time to facilitate the traceability of the hospital |
27 | *Sterilization effect detection | There is a sterilization effect test report for PTFE lumens with a diameter ≥ 1 mm and a length ≤ 2000 mm; there is a sterilization effect test report for stainless steel lumens with a diameter ≥ 1 mm and length ≤ 500 mm |
28 | *Hydrogen peroxide residue | After sterilization, there is no hydrogen peroxide residue in the surrounding air, which is harmless to the human body. |
29 | *Toxicological testing | After sterilization, the cells are non-toxic, ensuring that there is no residual hazard to patients and operators |
30 | #Identification | The user can quickly enter the operation interface through fingerprint entry, and record the physiological characteristics of the real operator, so as to truly realize the traceability of the "operator" |
31 | #Intelligent operating system | The use of Android control system and intelligent management can realize real-time recording and storage of machine operation and transmission of equipment operation data to the traceability system through wired and wireless communication methods to realize the traceability of "sterilization equipment" |
32 | #Video teaching | It can play various sensory control knowledge, operation guides, etc., so that users can quickly, clearly and intuitively understand the operation methods of the equipment, and solve various situations encountered in the use of the equipment, and improve the professionalism of the team |
33 | #Multiple ways of networking | Provide RJ45 wired network interface, WIFI module, 3G network module to meet the needs of hospitals for multiple networking methods. |
34 | #File output format | Internal memory capacity (data can be saved to a memory card) at least: 5000 cycles. After exporting the data of equipment operation, it is automatically generated in Excel file format, which is clear to read, no need to process again, saving time and effort |
35 | wheels | Mobile construction on wheels (2 wheels with brake mechanism) |
36 | Validation | Opotioal rapid bio-reader (1hour radout) |
37 | Power | 220V/50Hz 10A 2000W or Customer optional |
Ordinary verified
Business Type Manufacturer
Country / Region Beijing,China
Main Products Hospital Water Treatment System, Sterilization & Disinfection Equipment, Automatic Pharmacy Dispensing Equipment
Main Markets SouthAmerica,EasternEurope,SoutheastAsia,Africa,Oceania,MidEast
brand name : Baix
certification :
fob price :
min.order : 1 Piece(s)
warranty : 2 years
payment terms : L/C,T/T
Packaing : Wooden package
Specification : chamber size: 120 liters
Trademark : Baix
Production Capacity :
place of origin : Beijing
Manag Certifica : CFDA,ISO9001,ISO13485
Plasma sterilizer. PS-120 chamber size: 120 liters | ||
No | Content | Parameter |
1 | Application range | The product is used for rapid sterilization of surgical instruments, fear of heat, fear of moisture, orthopedic drills, electric knives, high-tech materials, vinyl materials, and rigid endoscopes Sterilization of anesthesia and respiratory equipment circuits, Sterilization of plastic and rubber products, Sterilization of other thermolabile instruments and expensive equipment: |
2 | Sterilization system | Low temperature plasma sterilization system |
3 | Chamber volume | Effective volume≥60L |
4 | Sterilization temperature | 50℃~60℃ |
5 | Chamber shape | Rectangular shape |
6 | Door | Single manual door |
7 | Door heating | Power 900W, preheating time ≤30min, heating film number ≥2, door panel temperature maintained within 55℃ to prevent condensation of hydrogen peroxide gas |
8 | Sterilization agent | Hydrogen peroxide with a concentration of ≥60%, sealed installation, with automatic identification system |
9 | Injection type | Cartridge injection: plastic package. Cartridges validity: 18months. Built-in intelligent chip will reminder system alarm when the cartridges are not valid any more. Automatic disposal of used containers in the disposal compartment: The product injection method has independent intellectual property rights, which can avoid disputes caused by property rights during the use process. |
10 | Sterilizer dosage | ≤2mL, dosage error <1%, PH<2.6, content drop rate <3.04% after being placed at 54℃ for 14 days, and provide a test report above the provincial level. |
11 | Plasma power | Power ≤500W, strong resolution ability, 0.01mg/cm2 residue in stainless steel after sterilization |
12 | Sterilization program | Three programs: standard, accelerated, extended: |
13 | Sterilization time | ≤60min |
14 | LCD display | ≥The 7-inch ultra-clear LCD screen makes the operation and viewing more clear and direct. Lively display. |
15 | Main body insulation | Two or more thermal insulation materials keep the cavity insulate, the thickness is ≥20mm, and the thermal insulation materials are required to have the characteristics of low thermal conductivity, good fire resistance, anti-aging, environmental protection and non-toxicity.。 |
16 | *Vacuum pump | Germany LEYBOLD |
17 | Vacuum pump protection device | Equipped with a vacuum pump protector, which can prevent the occurrence of oil reversal of the vacuum pump to the sterilization chamber due to the change of the power supply phase sequence |
18 | Oil mist filter | The product has an exhaust oil mist filter system, which can recover oil mist, prevent oil mist from entering the air, and through the pump suction, return the pump oil to the pump for repeated use to reduce fuel consumption. |
19 | Pressure sensing device | The product is equipped with a pressure sensing device that can sense the outdoor pressure, the pressure of the purification device and the sterilization chamber, and the measurement range is 0~101KPa |
20 | Vacuum control valve | Using high vacuum baffle solenoid valve to control the vacuum pipeline, the leakage rate <1.3*10-7Pa*L*S-1 |
21 | Pipe material | Use 304 stainless steel sanitary pipe and stainless steel sanitary clamp connection |
22 | Precision intake filter system | Filter level≤0.2um |
23 | *Plasma discharge monitoring device | Monitor the generation of plasma in the plasma sterilizer, and monitor the sterilization effect of the sterilizer by monitoring the plasma |
24 | *Number of RF sources | Double sets of radio frequency sources, increase the average density of plasma, enhance the penetration ability of plasma, and improve the sterilization ability |
25 | *AC and DC hybrid ignition device with self-check function | First use direct current to conduct the sterilization chamber, and then use alternating current to continuously generate plasma, making the generation of plasma easier and more stable |
26 | Printing system | Built-in thermographic printer: Various parameters such as sterilization time, inner tank temperature, liquid injection volume, vacuum pressure, and operators can be automatically printed out during the sterilization process. And can keep the printed records for more than five years for a long time to facilitate the traceability of the hospital |
27 | *Sterilization effect detection | There is a sterilization effect test report for PTFE lumens with a diameter ≥ 1 mm and a length ≤ 2000 mm; there is a sterilization effect test report for stainless steel lumens with a diameter ≥ 1 mm and length ≤ 500 mm |
28 | *Hydrogen peroxide residue | After sterilization, there is no hydrogen peroxide residue in the surrounding air, which is harmless to the human body. |
29 | *Toxicological testing | After sterilization, the cells are non-toxic, ensuring that there is no residual hazard to patients and operators |
30 | #Identification | The user can quickly enter the operation interface through fingerprint entry, and record the physiological characteristics of the real operator, so as to truly realize the traceability of the "operator" |
31 | #Intelligent operating system | The use of Android control system and intelligent management can realize real-time recording and storage of machine operation and transmission of equipment operation data to the traceability system through wired and wireless communication methods to realize the traceability of "sterilization equipment" |
32 | #Video teaching | It can play various sensory control knowledge, operation guides, etc., so that users can quickly, clearly and intuitively understand the operation methods of the equipment, and solve various situations encountered in the use of the equipment, and improve the professionalism of the team |
33 | #Multiple ways of networking | Provide RJ45 wired network interface, WIFI module, 3G network module to meet the needs of hospitals for multiple networking methods. |
34 | #File output format | Internal memory capacity (data can be saved to a memory card) at least: 5000 cycles. After exporting the data of equipment operation, it is automatically generated in Excel file format, which is clear to read, no need to process again, saving time and effort |
35 | wheels | Mobile construction on wheels (2 wheels with brake mechanism) |
36 | Validation | Opotioal rapid bio-reader (1hour radout) |
37 | Power | 220V/50Hz 10A 2000W or Customer optional |